Update on Eco-Counters' Status
Associated Project(s): 
Today, Sarthak met with a technical support staff from Eco-Counter to diagnose and address several malfunctioning counters around campus. They found the following:
- Wright St and Healey St East Side
- Problem: Flashing red light, counter could not detect sensors, corrosion on one of the connections between logger and sensors
 - Analysis: Corrosion caused a short circuit that depleted external battery and impacted logger's internal battery
 - Recommendation: Replace system with MULTI Evo post
 
 - First and Windsor
- Problem: pedestrian counter counting randomly
 - Analysis: Electromagnetic interference or issue with sensor
 - Recommendation: Wrap sensor in aluminium foil to mitigate interference. Inspect sensor and replace if needed
 
 - Illini Uninon North Side
- Problem: bicycle counter not counting
 - Solution: Adjusted settings of bicycle counter to resolve this issue
 
 - Main Quad East - Bevier Hall
- Problem: pedestrian counter was counting erratically and counting ghosts
 - Analysis: Nearby vegetation and spiderweb inside counter was moving in front of sensor and causing false counts
 - Recommendation: monitor counts to see if they have returned to normal
 
 